@article {1563, title = {Interference of ferric ions with ferrous iron quantification using the ferrozine assay.}, journal = {J Microbiol Methods}, volume = {95}, year = {2013}, month = {2013 Dec}, pages = {366-7}, abstract = {

The ferrozine assay is a widely used colorimetric method for determining soluble iron concentrations. We provide evidence for a heretofore unrecognized interference of ferric ions (Fe(3+)) on ferrous iron (Fe(2+)) measurements performed in the dark. Fe(3+) concentrations affected the absorbance measurements, which linearly increased with incubation time.

}, keywords = {Chemistry Techniques, Analytical, Colorimetry, Darkness, Diagnostic Errors, Ferric Compounds, Ferrous Compounds, Ferrozine, Ions, Iron, Time Factors}, issn = {1872-8359}, doi = {10.1016/j.mimet.2013.10.005}, author = {Im, Jeongdae and Lee, Jaejin and L{\"o}ffler, Frank E} }